CSM RO membrāna RE4040-BLN (2600GPD)

Ražotājs: TORAY
Produkta kods: RE4040-BLN
Šāda kombinācija neeksistē
230.00
278.30

CSM RO membrāna RE4040-BLN (2600GPD)

Low pressure grade RO element with extended area for brackish water

SPECIFICATIONS

GeneralFeatures:

  • Permeate flow rate: 2,600 GPD (9.8 m 3/day)
  • Nominal salt rejection: 99.3%
  • Effective membrane area: 85 ft2 (7.9 m2)
  • Membrane type: Thin-Film Composite
  • Membrane material: Polyamide (PA)
  • Element confguration: Spiral-Wound, FRP Wrapping
Parādīt visu aprakstu
APPLICATION DATA
 
Operating Limits: 
  • Max. Pressure Drop / Element - 15 psi (0.1 MPa)
  • Max. Pressure Drop / 24 0”V essel - 60 psi (0.41 Mpa)
  • Max. Operating Pressure - 600 psi (4.14 MPa)
  • Max. Feed Flow Rate - 18 gpm (4.09 m3/hr)
  • Min. Concentrate Flow Rate - 4 gpm (0.91 m3/hr)
  • Max. OperatinTg emperature - 113 oF (45 oC)
  • Operating pH Range - 3.0–10.0
  • CIP pH Range - 2.0–11.0
  • MaxT. urbidity - 1.0 NTU
  • Max. SDI (15 min) - 5.0
  • Max. Chlorine Concentration < 0.1 mg/L

Design Guidelines for Various Water Sources:

  • Wastewater Conventional (SDI < 5) - 8–12 gfd
  • Wastewater Pretreated by UF/MF (SDI < 3) - 10–14 gfd
  • Seawater, Open Intake (SDI < 5) - 7–10 gfd
  • Seawater, Beach Well (SDI < 3) - 8–12 gfd
  • Surface Water (SDI < 5) - 12–16 gfd
  • Surface Water (SDI < 3) - 13–17 gfd
  • Well water (SDI < 3) - 13–17 gfd
  • RO permeate (SDI < 1) - 21–30 gfd

Saturation Limits (Using Antiscalants)*:

  • Langlier Saturation Index (LSI) <+1.5
  • Stiff and Davis Saturation Index (SDSI) <+0.5
  • CaSO4 - 230% saturation
  • SrSO 4 - 800% saturation
  • BaSO4 - 6,000% saturation
  • SiO2 - 100% saturation

 

*The above saturation limits are typically accepted by proprietary antiscalant
manufacturers. It is the user’s responsibility to ensure proper chemical(s) and
concentration are dosed ahead of the membrane system to prevent scale
formation anywhere within the membrane system. Membrane elements fouled
or damaged due to scale formation are not covered by the limited warranty.